SPECIFICATIONS

Alarm Mode: light/light up

Brand Name: NONE

Color: White

Feature: Long Life

High-concerned chemical: None

Iginition gas: Hydrogen and air

Material: Aluminium-copper Alloy

Model: GC

Origin: Mainland China

Product name: Laboratory analysis Gas Chromatography

Samples: Volatile organic compounds

Size: 330mm* 280mm * 270mm

Temperature control range: 15 ° C ~ 399 ° C

Type: Other

With software: YES

customized support: OEM, ODM

material: STAINLESS STEEL

model number: GC-102AF

place of origin: Henan, China

power: flame ionization detector (FID)

type: Laboratory analysis instrument

Hello, Dear friends, please contact customer service to ask for product details before you place an order!
#detail_decorate_root .magic-0{margin-bottom:10px;overflow:hidden}#detail_decorate_root .magic-1{margin-bottom:10px;line-height:0}#detail_decorate_root .magic-2{margin-bottom:0}#detail_decorate_root .magic-3{position:relative;width:100%}#detail_decorate_root .magic-4{border-bottom-style:solid;border-bottom-color:#015198;font-family:Arial,Helvetica;font-size:32px;color:#015198;text-align:center;font-style:normal;font-weight:bold;border-bottom-width:2px;padding-top:8px;padding-bottom:4px}#detail_decorate_root .magic-5{width:750px}#detail_decorate_root .magic-6{overflow:hidden;width:750px;height:750px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-7{margin-top:0;margin-left:0;width:750px;height:750px}#detail_decorate_root .magic-8{vertical-align:top}#detail_decorate_root .magic-9{vertical-align:top;display:block;padding-right:4px;box-sizing:border-box;padding-left:4px}#detail_decorate_root .magic-10{vertical-align:top;padding-bottom:4px;box-sizing:border-box;padding-top:4px}#detail_decorate_root .magic-11{padding:0;margin:0;white-space:pre-wrap;font-size:14px}#detail_decorate_root .magic-12{font-size:18px}#detail_decorate_root .magic-13{overflow:hidden;width:750px;height:452.2357723577236px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-14{margin-top:0;margin-left:0;width:750px;height:452.2357723577236px}#detail_decorate_root .magic-15{width:750px;border-collapse:collapse}#detail_decorate_root .magic-16{min-height:18px;padding:5px 10px;width:275px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-17{text-align:center}#detail_decorate_root .magic-18{min-height:18px;padding:5px 10px;width:430px;min-height:18px;box-sizing:content-box}#detail_decorate_root .magic-19{min-height:18px;padding:5px 10px;width:275px;box-sizing:content-box}#detail_decorate_root .magic-20{min-height:18px;padding:5px 10px;width:430px;box-sizing:content-box}#detail_decorate_root .magic-22{overflow:hidden;width:750px;height:695px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-23{margin-top:0;margin-left:0;width:750px;height:710px}#detail_decorate_root .magic-24{overflow:hidden;width:750px;height:575px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-25{margin-top:0;margin-left:0;width:750px;height:590px}#detail_decorate_root .magic-26{overflow:hidden;width:750px;height:715px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-27{margin-top:0;margin-left:0;width:750px;height:730px}#detail_decorate_root .magic-28{overflow:hidden;width:750px;height:525px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-29{margin-top:0;margin-left:0;width:750px;height:540px}#detail_decorate_root .magic-30{overflow:hidden;width:750px;height:595px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-31{margin-top:0;margin-left:0;width:750px;height:610px}#detail_decorate_root .magic-32{font-size:16px}#detail_decorate_root .magic-33{overflow:hidden;width:750px;height:470px;margin-top:0;margin-bottom:0;margin-left:0;margin-right:0}#detail_decorate_root .magic-34{margin-top:0;margin-left:0;width:750px;height:470.00000000000006px}
Product Details
The GC102AF Gas Chromatograph by Laboao is a state-of-the-art analytical instrument designed for precise separation and analysis of vaporizable compounds without decomposition. It features a micro-machined design and incorporates a single hydrogen flame ionization detector (FID), making it a versatile and efficient tool for applications such as substance purity testing, mixture component separation, and compound identification. Ideal for preparative chromatography, the GC102AF ensures accurate and reliable results in various analytical chemistry scenarios.
Model
GC-102AF
Temperature control range
15 ° C ~ 399 ° C (increment 1 ° C) at room temperature
Temperature control accuracy
better than ± 0.1 ° C (200 ° C measured)
Temperature control area
column box, injector, detector
Detection limit
MFID ≤ 1 × 10-10g / s (sample: C16)
Baseline drift
≤ 2 × 10-12A / h
Our Advantages
1. Cutting-Edge Technology: The GC102AF Gas Chromatograph incorporates microcomputerized temperature control with unparalleled accuracy, exceeding industry standards at better than ±0.1°C. This ensures top-tier performance in analytical processes, providing precise and reliable results. 2. User-Friendly Interface and Advanced Features: The instrument is equipped with a keyboard that allows users to set various control parameters, including detector operation specifics. The machine goes beyond basic functionalities with self-diagnosis capabilities, power-off protection, file storage and recall, limit temperature settings, and FID auto-ignition. These features enhance operational ease and efficiency. 3. Intuitive Display: The large-screen Chinese character LCD display is a standout feature, offering a comprehensive view of critical information. Users can effortlessly monitor temperature control settings, actual values, TCD working current, FID amplifier sensitivity, and more. The intuitive interface contributes to an enhanced user experience. 4. Versatility in Injection Methods: The GC102AF supports diverse injection methods, providing flexibility in analytical approaches. Whether it's packed column filling, instantaneous vaporization injection, gas injection, or large-diameter capillary direct injection (0.53mm), the instrument adapts to varying analytical needs, making it a versatile choice for laboratories. 5. Advanced Connectivity and Data Processing: The open microcomputer system allows seamless integration with an RS-232 interface and F-2000 chromatography workstation. This facilitates two-way communication, control, and data processing. The advanced connectivity options ensure the chromatograph is not just a standalone instrument but part of a comprehensive analytical solution, maximizing efficiency in data management.
Company Profile
FAQ
Query: How does the GC102AF Gas Chromatograph ensure accurate temperature control, and what benefits does this precision offer in analytical processes? Response: The GC102AF employs microcomputerized temperature control with a remarkable accuracy better than ±0.1°C. This precision is pivotal in analytical applications, ensuring reliable and consistent results. It enhances the reproducibility of experiments and provides a solid foundation for precise compound separation and analysis. Query: Can you elaborate on the user-friendly features mentioned, especially the keyboard functionalities and advanced capabilities like self-diagnosis? Response: Certainly. The keyboard on the GC102AF allows users to set various control parameters, ensuring a tailored and user-friendly experience. Additionally, advanced features like self-diagnosis, power-off protection, and file storage enhance operational ease. The instrument's intelligence extends beyond basic functions, providing an efficient and secure environment for analytical tasks. Query: The display is highlighted as intuitive. How does the large-screen LCD contribute to a better user experience, and what critical information does it display? Response: The large-screen Chinese character LCD offers a comprehensive view, displaying critical information such as temperature control settings, actual values, TCD working current, and FID amplifier sensitivity. This intuitive interface simplifies monitoring, allowing users to grasp essential data at a glance, fostering a more efficient and user-friendly analytical environment. Query: The instrument mentions versatility in injection methods. Can you provide examples of scenarios where different injection methods are beneficial? Response: Certainly. The GC102AF's versatility shines in scenarios requiring diverse injection methods. For instance, packed column filling is suitable for specific separation needs, while instantaneous vaporization injection and large-diameter capillary direct injection offer flexibility in sample introduction. This adaptability caters to varying analytical requirements, making the instrument suitable for a broad range of applications. Query: The connectivity options are highlighted. How does the open microcomputer system benefit laboratories, and what advantages does integration with RS-232 and the F-2000 chromatography workstation bring? Response: The open microcomputer system enhances the instrument's capabilities by allowing seamless integration with RS-232 and the F-2000 chromatography workstation. This connectivity facilitates two-way communication, control, and data processing. Laboratories benefit from an integrated and efficient analytical solution, streamlining data management and ensuring the chromatograph is part of a comprehensive analytical workflow.